Measurement Specialties 9116 Bedienungsanleitung Seite 40

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 146
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 39
Measurement Specialties Inc. Model 9116 User’s Manual
Page 28 www.MEAS-SPEC.com
3.2 Detailed Command Description Reference
All commands applicable to the Model 9116 Intelligent Pressure Scanner modules are
described on the following pages. They are summarized in the following table. For
convenience, this table is also repeated in Appendix B.
TYPE
COMMAND ID
COMMAND FUNCTIONS
TCP/IP
Commands
A
Power-Up Clear
B
Reset
C
Configure/Control Multi-Point Calibration
(4 sub-commands)
V
Read Transducer Voltages
Z
Calculate and Set Gains (Span Cal)
a
Read Transducer Raw A/D Counts
b
Acquire High Speed Data
c
Define/Control Autonomous Host Streams
(6 sub-commands)
h
Calculate and Set Offsets (Re-zero Cal)
m
Read Temperature A/D Counts
n
Read Temperature Voltage
q
Read Module Status
r
Read High Precision Data
t
Read Transducer Temperature
u
Read Internal Coefficients
v
Download Internal Coefficients
w
Set/Do Operating Options/Functions
UDP/IP
Commands
psi9000
Query Network
psireboot
Reboot Specified Module
psirarp
Change Specified Module’s IP Address
Resolution Method (then Reboot)
Seitenansicht 39